Size Exclusion Resins

Download for More Info

Size exclusion resins are based on the size of the target molecules, from the largest to the smallest peak in order to achieve the purpose of separation.

  • Size exclusion resins are often used in the subsequent purification stage with less impurities.

  • Size exclusion resins are used for the purification of smaller samples.

  • In group separation (such as desalination) can also be used in the coarse purification stage.

  • The addition of 150 mM NaCl to the buffer can effectively reduce the non-specific adsorption of the target protein.

Ion Exchange Resins

Download for More Info

Ion exchange resins is one of the most widely used methods for protein separation and purification. Different proteins have different isoelectric points, different molecular sizes, different charge density distributions in the same mobile phase, different charge amounts, different binding strengths to ion exchange resin with opposite charges, and different retention times when eluting in the mobile phase, thus allowing separation.

VDO supplies 6 types of ligands, which are DEAE, CM, Q, SP, Focurose FF, Focurose HF and Focurose HPR , which are a combination of 3 substrates and a variety of ion exchange resin to precisely match the downstream technology of bioprocesses.

Hydrophobic Interaction Resins

Download for More Info

Hydrophobic interaction resins separates proteins based on differences in hydrophobicity, i.e., based on reversible interactions between proteins and hydrophobic groups on the surface of hydrophobic interaction resins.

Hydrophobicity isenhanced at high ionic strengths and therefore binding in a high ionic strength environment is usually eluted by reducing the ionic strength. The unique adsorption separation mode makes hydrophobic interaction resins an ideal purification method after ammonium sulfate chromatography or after ion exchange high salt elution.

Affinity Resins

Download for More Info

Affinity resins were established and developed based on the principle of specific adsorption between biomolecules and other ligand molecules (e.g. antigen and antibody, enzyme and substrate, hormone and receptor, complementary chain in nucleicacid, polysaccharide and protein complex, etc.). The purification of target molecules is achieved by specific adsorption between the ligand on the medium and the target molecule. Due to this specific force, affinity resins are characterized by high selectivity and high activity recovery.

Name
Ni-IDA
Ni-IMAC
Ni-TED
Chelation ratio
3:3
4..2
5..1
Reducing agent (mM)
Avoid
1
20
Chelating agent(mM)
Avoid
5
100
pH range
3-12(working)
2-14(cleaning)
3-12(working)
2-14(cleaning)
3-12(working)
2-14(cleaning)
3-12(working)
2-14(cleaning
Cleaning regeneration
9 steps (nickel removal - cleaning - regeneration)
9 steps (nickel removal-
cleaning - regeneration)
5 steps (cleaning)
Application scope
Conventional His-tagged Protein Purification(Active Conditions)
Routine His-tagged protein purification (active and denaturing conditions)
Can be used for high reductant, chelator His-tagged protein samples and eukaryotic His-tagged protein purifcation (low abundance samples and denaturant samples are less effective)
Product Number
Product Name
Spec
Load per
Particle Size Range μm
Maximum flow rate (cm/h)
Withstand Pressure Mpa
pH Stability Long-term (Shot-term)
Application
HQ060311025M HQ060311100M HQ060311500M HQ060311001L HQ060311005L HQ060311020L
Ni Focurose
FF (IDA)
25mL 100mL 500mL 1L 5L 20L
≥30mg His-tagged proteins
45-165
375
≤0.3
3-12 (2-14)
Purification of His-tagged proteins
HQ060312025M HQ060312100M HQ060312500M HQ060312001L HQ060312005L HQ060312020L
Ni Focurose
FF (IMAC)
25mL 100mL 500mL 1L 5L 20L
≥40mg His-tagged proteins
45-165
250-400
≤0.3
3-12 (2-14)
Large-scale purification of His-tagged proteins
HQ060313025M HQ060313100M HQ060313500M HQ060313001L HQ060313005L HQ060313020L
Ni Focurose
FF(TED)
25mL 100mL 500mL 1L 5L 20L
≥10mg His-tagged proteins
45-165
600
≤0.3
3-12 (2-14)
Resistant to 100mM EDTA and 10mM DTT,direct1M NaOH thorough cleaning without nickel removal.